At start-up the system recovers its design volume; six months later the same feed yields only seventy or eighty percent. It is a common story, and it rarely has a single cause. Rather than replacing equipment or adding chemicals straight away, work through a fixed sequence to locate the bottleneck.

Step 1: close the water balance

Diagnosis starts with numbers. Over the same period — ideally at least a week covering normal production and cleaning days — record:

  • Feed: total water entering the recovery system
  • Recovered water: water actually delivered to the reuse point
  • Concentrate or discharge: water leaving the system without being recovered
  • Storage change: start and end levels of each holding tank

Feed should roughly equal recovered water plus concentrate plus storage change. A large gap means the measurement itself is wrong — drifting flow meters, unmetered bypasses — and must be fixed first, or every later conclusion is unreliable.

Step 2: split the yield into parts

Recovered-water yield can be broken down as:

Yield = feed capture × system recovery × availability

Part Meaning Typical problems
Feed capture How much of the water that should enter the system actually does Missed connections, mixed streams sent to drain, overflowing holding tanks
System recovery How much of the feed becomes acceptable recovered water Concentration ratio forced down, off-spec condensate dumped
Availability How much of the time the system runs normally More frequent cleaning stops, faults, waiting for feed

Whichever part has dropped most tells you where to look.

Bottleneck 1: scaling holds the concentration ratio down

Scale on heat-transfer surfaces reduces heat transfer, so the system must run at a lower concentration ratio or be cleaned more often — and recovered water falls. Check:

  • Whether the heat-transfer temperature difference or compressor load rises month by month
  • Whether run time between cleanings keeps getting shorter
  • Whether feed hardness, silica or sulfate has changed (new raw materials or process recipes)

Remedies include pretreatment, pH control, adjusted operating temperature and a planned cleaning routine.

Bottleneck 2: condensate fails the quality target

If the feed contains volatile components such as ammonia or low-boiling organics, some carry over with the vapor into the condensate. When condensate misses the reuse point’s specification it is discharged, and recovery drops.

Compare against the quality the reuse point actually needs, not a general discharge standard. Sometimes a short polishing step for one or two parameters is enough to bring the condensate back into use.

Bottleneck 3: foaming and carry-over

Surfactants and some organics make evaporators foam; droplets are carried with the vapor, contaminating condensate and sometimes forcing operators to cut throughput. Watching the sight glass and swings in condensate conductivity often reveals when foaming occurs.

Bottleneck 4: supply and demand out of step

The recovery system may be fine, but recovered water is produced on the night shift while the reuse point draws on the day shift; once the holding tank fills, surplus water is discharged. This apparent low yield is a scheduling problem, solved by more buffer storage or by shifting when the reuse point draws water.

Diagnostic checklist

  1. Does the water balance close within an acceptable error?
  2. Which of the three parts has dropped most?
  3. Monthly trends in temperature difference, compressor load and cleaning interval
  4. Any recent change in feed water quality
  5. Condensate conductivity and key parameters against the reuse point’s requirements
  6. Holding-tank overflow or discharge records and their timing

What to bring to a first discussion

  • At least a week of feed, recovered-water and concentrate flow records
  • Recent analyses of feed and condensate
  • Cleaning and downtime logs
  • The reuse point’s quality requirements and usage times

With these side by side, the bottleneck usually shows itself — and adjusting operation, adding pretreatment or expanding storage can then be decided on evidence.